Customized Electrical Safety Test Equipment Temperature Measurement Test Corner
Detail produk:
Place of Origin: | China |
Nama merek: | KingPo |
Sertifikasi: | Calibration Certificate |
Syarat-syarat pembayaran & pengiriman:
Minimum Order Quantity: | 1 |
---|---|
Harga: | To be quoted |
Kemasan rincian: | paket karton pengaman atau kotak kayu lapis |
Payment Terms: | T/T |
Informasi Detail |
|||
Standard: | IEC60335-1:2004 chapter 11 | thermocouple: | K, T, J type(optional) |
---|---|---|---|
sheet copper φ: | 15mm | sheet copper thickness: | 1mm |
Menyoroti: | Abrasi Uji Resistance Mesin,electrical safety analyzer |
Deskripsi Produk
Electrical Temperature Measurement Test Corner
IEC60335-1:2004 Electrical Appliance Tester Temperature Measurement Test Corner
Product information:
The temperature measurement corner conforms to the standard requirement of IEC60335-1:2004 chapter 11. It is designed and manufactured to provide the required environment for the temperature rising test of all kinds of electrical, electrical products. It can be customized according to the different testing samples.
Technical parameters:
1. Size: 600X600X1000mm,800X800X1000mm,1000x1000x1200mm(it can be customized)
2. Thermocouple: the diameter of the thermocouple is less than 0.3mm. There are three kinds of the thermocouple: K, T, J (any one of it can be chosen)
3. The thermocouple arrangement: All leads on a connection line(optionally equipped with thermocouple plug and socket)
4. The sheet copper used for temperature measurement: the diameter of 15mm and the thickness of 1mm.
5. The number of temperature measuring points:20,32,48,64(it can be customized)
6. The arrangement of temperature measuring points:100*100mm or 76*76mm square(it can be customized)
7. Plywood:The thickness is 20mm and the front side is painted with Berlin black and the reverse side is with gray film back.
8. The movable part: there are 4 removable wheels installed on the bottom of the device.
9. The height of the wheel is about 100mm. The top plate is equipped with hook whose load bearing is 15Kg.
10. Temperature patrol system needs to be equipped additionally
(optionally equipped with 48 road tour temperature table)