High Effcient Light Testing Equipment Axial Strength Of Edison Caps

High Effcient Light Testing Equipment Axial Strength Of Edison Caps

MOQ: 1
harga: To be quoted
kemasan standar: paket karton pengaman atau kotak kayu lapis
Periode pengiriman: 7 hari kerja
metode pembayaran: T/T
Kapasitas Pasokan: 50 pcs per bulan
Informasi Rinci
Tempat asal
Cina
Nama merek
kingpo
Sertifikasi
iso9001 ce
Place of origin:
Guangdong,China(mainland)
Standard:
IEC62560
Menyoroti:

temperature rise test equipment

,

LED Testing Equipment

Deskripsi Produk

 

Axial Strength of Edison Caps

 

The lamps shall be screwed into gauge of Table 4. After full insertion an axial force of Table 4
is applied to the central contact. See
IEC62560 Figure 7.
In case axial strength of the cap does not decrease when the unmounted cap was assembled
to the finished lamp, test results on the unmounted cap can be applied.
NOTE The gauges are used to hold the lamp. Calibration is not required.
Compliance:
After this test the insulation around the central contact shall remain intact. The application of
the torque test in 9.2.1 shall not lead to impressing the bottom part of the cap into the shell.

 

 

 

Produk
rincian produk
High Effcient Light Testing Equipment Axial Strength Of Edison Caps
MOQ: 1
harga: To be quoted
kemasan standar: paket karton pengaman atau kotak kayu lapis
Periode pengiriman: 7 hari kerja
metode pembayaran: T/T
Kapasitas Pasokan: 50 pcs per bulan
Informasi Rinci
Tempat asal
Cina
Nama merek
kingpo
Sertifikasi
iso9001 ce
Place of origin:
Guangdong,China(mainland)
Standard:
IEC62560
Minimum Order Quantity:
1
Harga:
To be quoted
Kemasan rincian:
paket karton pengaman atau kotak kayu lapis
Waktu pengiriman:
7 hari kerja
Payment Terms:
T/T
Menyediakan kemampuan:
50 pcs per bulan
Menyoroti

temperature rise test equipment

,

LED Testing Equipment

Deskripsi Produk

 

Axial Strength of Edison Caps

 

The lamps shall be screwed into gauge of Table 4. After full insertion an axial force of Table 4
is applied to the central contact. See
IEC62560 Figure 7.
In case axial strength of the cap does not decrease when the unmounted cap was assembled
to the finished lamp, test results on the unmounted cap can be applied.
NOTE The gauges are used to hold the lamp. Calibration is not required.
Compliance:
After this test the insulation around the central contact shall remain intact. The application of
the torque test in 9.2.1 shall not lead to impressing the bottom part of the cap into the shell.